Same day dispatch Card & Apple Pay accepted

All certificates

Independent laboratory testing

CJC-1295 (DAC) Certificate of Analysis

CJC-1295 (DAC) is independently tested by Ozcanium Analytics, an independent Australian laboratory, at 80.62% purity by UPLC-MS/MS, analysed 28 August 2026 on lot 25/08/2026, net content 5.29 mg, verification code OZ-HPLCMS-TPA5; bacterial endotoxin below 15.0 EU per vial by kinetic chromogenic LAL, analysed 28 August 2026, verification code OZ-ENDOTX-TPA7. The reports are published here in full, as issued.

Independent laboratory report

CJC-1295 (DAC) is independently tested by Ozcanium Analytics, an independent Australian laboratory, at 80.62% purity by UPLC-MS/MS, analysed 28 August 2026 on lot 25/08/2026, net content 5.29 mg, verification code OZ-HPLCMS-TPA5; bacterial endotoxin below 15.0 EU per vial by kinetic chromogenic LAL, analysed 28 August 2026, verification code OZ-ENDOTX-TPA7.

Issued by Ozcanium Analytics. Covers every vial size of this compound; each report opens as the laboratory issued it.

Enter a code in the Ozcanium Analytics verification portal (opens in a new tab) to confirm the report against their own records.

What was tested

The catalogue record for CJC-1295 (DAC), so the report above can be matched to what is actually in the vial.

Form
Lyophilised powder
CAS Number
863288-34-0
Sizes
10mg / vial
Packaging
Sterile, tamper-evident research vial

One report covers every size listed above — it is the same product filled into different vials, so the assay is commissioned per compound rather than per size.

CJC-1295 (DAC) testing — common questions

Is CJC-1295 (DAC) tested?
Yes. CJC-1295 (DAC) is independently tested by Ozcanium Analytics, an independent Australian laboratory, at 80.62% purity by UPLC-MS/MS, analysed 28 August 2026 on lot 25/08/2026, net content 5.29 mg, verification code OZ-HPLCMS-TPA5; bacterial endotoxin below 15.0 EU per vial by kinetic chromogenic LAL, analysed 28 August 2026, verification code OZ-ENDOTX-TPA7. The reports are published on this page as issued, rather than summarised or sent on request.
What does the endotoxin test on CJC-1295 (DAC) measure?
Endotoxins are fragments of bacterial cell wall. They are not removed by sterilisation and they provoke a response in cell culture and in-vivo work at very low concentrations, which is why they are measured separately from sterility. The figure matters more for a diluent than for anything else in a research fridge: whatever it carries is added to every vial it reconstitutes, so its endotoxin load is inherited by every experiment downstream of it.
How do I check the CJC-1295 (DAC) report is genuine?
Each report carries the laboratory's own reference — OZ-HPLCMS-TPA5 and OZ-ENDOTX-TPA7 — printed beside it on this page. Enter a code in the Ozcanium Analytics verification portal and the document is confirmed against their records rather than ours, which is the entire reason a code is published alongside it.

Next

Tested Peptides runs no analysis of its own: every certificate in the certificate library is issued by Ozcanium Analytics, an independent Australian laboratory, and is replaced with the current one each time a compound is re-tested. For a question about this report, email [email protected].

All products are supplied for laboratory research use only. They are not therapeutic goods and are not for human or veterinary use.